Service
Drain pump test run
Button operation
[
1
]
It is possible to run just the drain pump without running the indoor unit’s fan.
Carry this out after completing the indoor and outdoor electrical work.
* Refer to the indoor unit’s installation manual, and conrm that the water is accurately drained, and that no water is leaking
from the pipe connections.
F1 F2 F3 F4
unemecivreS
rosruC
:unemniaM
Test run
Input maintenance info.
Function setting
Check
Self check
F1 F2 F3 F4
Test run menu
Cursor
Service menu:
Test run
Drain pump test run
P
Service
Main
Sub
F1 F2 F3 F4
Drain pump test run
Drain pump Off
Return:
Pump On/Off:
F1 F2 F3 F4
Drain pump test run
Drain pump On
Pump On/Off:
Check the drain pump’s operation state.
End the drain pump test run.
Press the button.
The drain pump test run will be nished, and then the “Test run menu” screen will
appear.
* The drain pump test run will automatically stop after two hours.
[
2
]
Select "Drain pump test run" with the F1 or F2 button, and press the
button.
Select "Service" from the Main menu (refer to page 17, and press the
button.
Select "Test run" with the
F1
or
F2
button, and press the button.
[
3
]
Start the drain pump test run.
Press the button.
* The drain pump will be prepared for the “Drain pump test run”, and the test run
will start.
[
4
]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric Mr.Slim PAR-30MAA and is the answer not in the manual?

Mitsubishi Electric Mr.Slim PAR-30MAA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMr.Slim PAR-30MAA
CategoryRemote Control
LanguageEnglish

Related product manuals