EXTERNAL ADJUSTMENT
external adjustment1.9.2
climate system 1
climate system 2
climate system 3
climate system 4
°C
°C
climate system
Setting range: -10 to +10.
Or desired room temperature if the
room sensor is installed. See illustra-
tion.
Default value: 0
Menu
1.9.2
Connecting an external contact, for example, a room thermostat or a timer allows
you to temporarily or periodically raise or lower the room temperature while
heating. When the contact is on, the heating curve offset is changed by the
number of steps selected in the menu. If a room sensor is installed and activated
the desired room temperature (°C) is set.
If there is more than one climate system the setting can be made separately for
each system.
MIN. FLOW LINE TEMP.
min. flow line temp. heating1.9.3.1
climate system 1
climate system 2
climate system 3
climate system 4
°C
°C
°C
°C
20
20
20
20
min. flow line temp. cooling1.9.3.2
climate system 1
climate system 2
climate system 3
climate system 4
°C
°C
°C
°C
18
18
18
18
heating
Setting range: 5-70 °C
Default value: 20 °C
cooling (accessory required)
Factory setting: 18 °C
Menu
1.9.3
NIBE VVM 320Chapter 3 | VVM 320 at your service36

Table of Contents

Other manuals for Nibe VVM 320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe VVM 320 and is the answer not in the manual?

Nibe VVM 320 Specifications

General IconGeneral
BrandNibe
ModelVVM 320
CategoryControl Unit
LanguageEnglish

Related product manuals