3. Instructions
148
CS/CJ/NSJ Series Instructions Reference Manual (W474)
Example Programming
z AND LD
i
• The AND LOAD instruction can be used repeatedly. In programming method (2) above, however, the
number of AND LOAD instructions becomes one less than the number of LOAD and LOAD NOT
instructions before that.
• In method (2), make sure that the total number of LOAD and LOAD NOT instructions before AND
LOAD is not more than eight.
• To use nine or more, program using method (1).
• If there are nine or more with method (2), then a program error will occur during the program check by
the Peripheral Device.
z OR LD
i
• The OR LOAD instruction can be used repeatedly. In programming method (2) above, however, the
number of OR LOAD instructions becomes one less than the number of LOAD and LOAD NOT
instructions before that.
• In method (2), make sure that the total number of LOAD and LOAD NOT instructions before OR
LOAD is not more than eight.
• To use nine or more, program using method (1).
• If there are nine or more with method (2), then a program error will occur during the program check by
the Peripheral Device.
0.00 0.02 0.04
0.01 0.03 0.05
5.00
Coding Example (1) Coding Example (2)
Instruction Operand
LD 0.00
OR NOT 0.01
LD NOT 0.02
OR 0.03
AND LD ---
LD 0.04
OR 0.05
AND LD ---
.
.
.
.
OUT 5.00
Instruction Operand
LD 0.00
OR NOT 0.01
LD NOT 0.02
OR 0.03
LD 0.04
OR 0.05
.
.
.
.
AND LD ---
AND LD ---
.
.
.
.
OUT 5.00
0.00 0.01
0.02 0.03
0.04 0.05
5.01
Coding Example (1) Coding Example (2)
Instruction Operand
LD 0.00
AND NOT 0.01
LD NOT 0.02
AND NOT 0.03
OR LD ---
LD 0.04
AND 0.05
OR LD ---
.
.
.
.
OUT 5.01
Instruction Operand
LD 0.00
AND NOT 0.01
LD NOT 0.02
AND NOT 0.03
LD 0.04
AND 0.05
.
.
.
.
OR LD ---
OR LD ---
.
.
.
.
OUT 5.01