84
CIO Area Allocations Section 4-1
Socket Service Request
Switches 1 to 8 (CPU Unit
to Ethernet Unit)
When a socket service request is executed by control bit manipulation, it is the
following bits that are manipulated. For details, refer to Operation Manual,
Construction of Applications, SECTION 6.
05 DNS server error ON Unit ON when the following errors occur during DNS server
operation:
An illegal server IP address is set.
A timeout occurs during communications with the
server.
OFF Unit OFF when DNS server operation is normal.
06 Routing table error ON Unit ON if the routing table information is incorrect.
OFF Unit OFF when the routing table is normal.
07 to 10 (Not used.) --- --- ---
11 SNTP server error ON Unit ON when the following errors occur during SNTP
server operation:
An illegal server IP address or host name is set.
A timeout occurs during communications with the
server.
OFF Unit OFF when SNTP server operation is normal.
12 SMTP server error ON Unit ON when the following errors occur during SMTP
server operation:
An illegal server IP address or host name is set.
A timeout occurs during communications with the
server.
The verification time from the server has expired
(when POP before SMTP is set).
OFF Unit OFF when SMTP server operation is normal.
13 POP server error ON Unit ON when the following errors occur during POP server
operation:
An illegal server IP address or host name is set.
A server verification error (user name or password)
occurs.
A timeout occurs during communications with the
server.
OFF Unit OFF when use of the POP server is normal.
14 Address disagreement ON Unit ON if the remote IP address is set to automatic genera-
tion but the local IP address host number and FINS
node address do not agree.
OFF Unit OFF under all other circumstances.
15 EEPROM error ON Unit ON if an error has occurred in the EEPROM memory.
OFF Unit OFF when the EEPROM memory is normal.
Bit Error Status Manipulated by Unit operation
15 14 13 12 11 10 09 08
UDP Open Request Switch
TCP Passive Open Request Switch
TCP Active Open Request Switch
Send Request Switch
Receive Request Switch
Close Request Switch
n+19 to n+22
07 06 05 04 03 02 01 00

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals