54
Converting from Previous Models Section 2-11
Abnormal Execution $ ping 130.25.36.8 ; Executes PING command
PING 130.25.36.8: 56 data bytes
Enter Ctrl+C Key to cancel.
––––130.25.36.8 PING Statistics––––
9 packets transmitted, 0 packets received, 100% packets loss
$
Refer to operating system documentation for your host computer for details
about using the host computer’s PING command.
2-11 Converting from Previous Models
The specifications for these Ethernet Units (CS1W-ETN21 and CJ1W-ETN21)
are compatible with those for previous models (CS1W-ETN01/ETN11 and
CJ1W-ETN11), so previous models being used with existing equipment can
be easily replaced by the new models. Many of the specifications for the new
Ethernet Units have been expanded, however, so there will be a number of
limitations if the Unit is simply replaced.
In particular, the CPU Bus Unit System Setup Area is formatted for the previ-
ous models, so there is no way to make the settings for the expanded specifi-
cations.
To remove these limitations, it is necessary to change the CPU Bus Unit Sys-
tem Setup format from “ETN11 mode” to “ETN21 mode.” Refer to Changing
the CPU Bus Unit System Setup Area Format below for instructions on how to
make the change.
If the format change is from ETN11 mode to ETN21 mode, then there will be
no effect on previous applications. If the change is from ETN21 mode to
ETN11 mode, however, then certain limitations will go into effect.
The following table shows the limitations that apply when operating in ETN11
mode.
Item Specifications in ETN11 mode
Baud rate Automatic detection (100Base-TX or
10Base-T)
Subnet mask CIDR is not used.
Operation is performed with the default net-
work mask if the subnet mask specification is
less than the network mask for each class.
FINS node address setting range 1 to 254
IP address conversion: Automatic
generation method
Dynamic only
TCP keep-alive No time setting (Uses default setting)
FINS/TCP Server only for all connections (Uses default
setting)
TCP socket services Socket option (keep-alive setting): Yes
Number of Bytes Received at TCP Socket
Nos. 1 to 8: Yes
Data Received Flag: Yes
Socket high-speed option: No
FTP server function Port No. setting: No (Uses default setting)

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals