53
Communications Test Section 2-10
If the remote node returns a normal response to the PING command, then the
nodes are physically connected correctly and Ethernet node settings are cor-
rect.
2-10-2 Ethernet Unit
The Ethernet Unit automatically returns the echo response packet in
response to an echo request packet sent by another node (host computer or
other Ethernet Unit). An echo request packet can be sent to another node by
issuing the FINS command to execute the PING command from the PLC.
Refer to page 184 for details on the PING command.
2-10-3 Host Computer
The PING command can be executed from the host computer to send an
echo request packet to an Ethernet Unit. The method for using the PING com-
mand from a UNIX computer is given next.
Method
Input the following at the host computer prompt ($):
$ ping IP_address(host_name)
The destination is specified by its IP address or host name. If the host name is
used, the host name must be defined in file /etc/hosts.
Note The PING command is not supported by some host computers.
Application Examples
These examples show sending the PING command to the node at IP address
130.25.36.8. The “$” in the example represents the host computer prompt.
User inputs are underlined. Comments are placed after semicolons.
Normal Execution $
ping 130.25.36.8 ; Executes PING command
PING 130.25.36.8: 56 data bytes
64 bytes from 130.25.36.8: icmp_seq=0. time=0.ms
64 bytes from 130.25.36.8: icmp_seq=0. time=0.ms
...
...
...
64 bytes from 130.25.36.8: icmp_seq=0. time=0.ms
Enter Ctrl+C Key to cancel.
––––130.25.36.8 PING Statistics––––
9 packets transmitted, 9 packets received, 0% packets loss
round–trip (ms) min/avg/max = 0/1/16
$
TCP UDP
ICMP
IP
Ethernet
Echo response
Echo request
Remote Node
(host computer or Ethernet Unit)
Ethernet Unit
PLC

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals