184
Command/Response Reference Section 7-3
Parameters
Socket Option (Command) The socket option specified as 1 byte. The setting is not valid for this com-
mand. Set to 0.
TCP Socket Number
(Command)
The TCP socket number to be closed specified as 1 byte between 1 and 8.
Results Storage Area
(Command)
The area in which the results of the command execution are stored. The first
byte specifies the memory area and data type (variable type). The 2nd to 4th
bytes specify the beginning address of the results storage area. Refer to
page 160 for details about the variable types and addresses that can be spec-
ified.
Precautions
Any other processing, such as sending or receiving data, being carried out
when this close command is executed will be forcibly ended and a code will
be stored in the results storage area to indicate that this processing was forc-
ibly ended.
Response Codes
Results Storage Area Response Codes
7-3-18 PING
Equivalent processing to the UNIX computer PING command (see below).
Command Block
Response code Description
0000 Normal
0105 Local IP address setting error
0302 CPU Unit error; execution not possible.
1001 Command too large
1002 Command too small
1100 The TCP socket number is out of range.
1101 The variable type for the results storage area is out of range.
1103 Non-zero bit address specified for the results storage area.
2210 No connection could be established to the specified socket.
2211 High traffic at Unit; cannot execute service.
2240 Socket service mode is incorrect; cannot execute service.
(With unit version 1.5 or later, the high-speed socket service
option was enabled and a socket service was used with a
CMND(490) instruction.)
Response code Description
0000 Normal
Destination IP address
Timeout
value
Command
code
27 20

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals