EasyManuals Logo
Home>Omron>Network Hardware>CS Series

Omron CS Series User Manual

Omron CS Series
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
131
Using FINS Applications Section 6-5
â–  System Configuration Example 2: Using Routing Tables
In this example, an online connection is made via the Ethernet to a PLC on a
Controller Link network (PLC 3 below) from a CX-Programmer or CX-Integra-
tor connected to the Ethernet network.
Conditions
• FINS/UDP method
• IP address conversion: Automatic generation method (dynamic)
CX-Programmer's Change PLC Dialog Box
CX-Programmer's Unit Setup
Setup Tab
Same as for System Configuration Example 1.
Routing Table Settings and Transfer to Each PLC
Set the routing tables with CX-Integrator, and transfer them.
1. Using CX-Integrator, connect online, and select Routing table − Settings.
Then create FINS local routing tables (a local network table and a relay
network table).
Example: PLC 1 Routing Table Settings
Settings for target PLC (PLC3)'s Change PLC Dialog Box Setting
PLC name PLC3
Network classification Ethernet
Network Tab FINS destination FINS transmission
source address
1
Network number 2
Node address 3
Frame length 2,000 bytes
Response monitor time 2 seconds
Driver Tab Workstation node address 1
Automatic generation method Not selected
IP address 192.168.250.2
(Ethernet Unit IP
address)
Port number 9600
CX-Programmer or CX-Integrator
Ethernet port
Node address: 1
IP address: 192.168.250.1
Ethernet (network address 1)
Routing
according to
routing table
Controller
Link Unit
Ethernet Unit
IP address conversion: Automatic generation method (dynamic)
Gateway between networks
PLC1
Controller Link Unit
Target PLC
Controller Link Unit
Node address 2
Node address 3
Controller Link
(
network address 2
)
PLC2
PLC3
Ethernet Unit node address: 2
Ethernet Unit IP address: 192.168.250.2
Ethernet Unit unit number: 0
Controller Link Unit node address: 1
Controller Link Unit unit number: 1
Routing to final network address 2
requires relaying through node
address 2 of relay network address
1 (Ethernet Unit).

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals