63
Setup Section 3-1
Note (1) The setting to enable or disable dynamic changing of remote IP address-
es is available for Ethernet Units with Unit Ver. 1.3 or later.
(2) Make settings using the unit settings function in the CX-Programmer (to
be included in version 5.0 and higher) or using the Web function (refer to
Appendix G Ethernet Unit Web Function).
(3) The Enable CIDR Option and High Speed Option for performance of
socket service are supported starting with unit version 1.5.
Conversion Select any of the following as the method for finding and converting IP
addresses from FINS node addresses. (Enabled for FINS/UDP only.)
Automatic generation (dynamic): Auto (dynamic)
Automatic generation (static): Auto (Static)
IP address table method: Table used
Combined method: Mixed
Auto (dynamic)
Destination IP Address
(Change Dynamically)
Select to dynamically change the remote (destination) IP address for
FINS/UDP. To prohibit dynamic changes, deselect this box.
Checked
(Change Dynami-
cally)
Baud Rate Select the Ethernet baud rate for the Ethernet Unit.
Select either automatic detection or 10Base-T. (For 100Base-TX, select
automatic detection.)
Auto
TCP/IP keep-alive Set the liveness-checking interval. When socket services using either
FINS/TCP or TCP/IP are used, the connection will be terminated if there
is no response from the remote node (either a server or client) within the
time set here. (Enabled for socket services using FINS/TCP or TCP/IP
only.)
Setting range: 0 to 65,535 minutes
This setting applies to the keep-alive setting for each connection set
with the FINS/TCP tab.
0
(120 minutes)
IP Address Table Set the IP address table that defines the relationship between FINS
node addresses and IP addresses.
With FINS/UDP, this is enabled only when the IP address table method
is set as the IP address conversion method.
None
IP Router Table Set when the Ethernet Unit is to communicate through the IP router with
nodes on another IP network segment.
None
FTP Login Sets the login name for connecting to the Ethernet Unit by FTP. None
Password Sets the password for connecting to the Ethernet Unit by FTP. None
(“CONFIDENTIAL”)
Port No. Set the FTP port number for the Ethernet Unit.
There is normally no need to change this number.
Two ports are used for FTP: a control port and a data transfer port. This
setting sets only the control port, and then the data transfer port uses
the number that is one less than the control port.
0
(Number 21 is
used.)
High-speed Socket Ser-
vices
Selecting this option improves the performance of processing for send-
ing and receiving using specific bits for socket services. For information
on communications performance, refer to 6-9-5 Times Required for
Sending and Receiving for Socket Services in the Ethernet Units Con-
struction of Applications Operation Manual. When the High Speed
Option is selected, socket services that are implemented using a
CMND(490) instruction will cause an error.
Disabled
Item Contents Default

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals