CompoWay/F
2.4 Response Code List
2-25
2.4 Response Code List
Normal Completion
Error Occurred
Response
code
Name Description
Error
detection
priority
0000 Normal completion No errors were found. None
Response
code
Name Description
Error
detection
priority
0401 Unsupported command The service function for the relevant command is
not supported.
1
1001 Command too long The command is too long. 2
1002 Command too short The command is too short. 3
1101 Area type error Wrong variable type 4
1103 Start address out-of-range error The read/write start address is out of range. 5
1104 End address out-of-range error The write end address (write start address +
number of elements) exceeds the final address
of the variable area.
6
1003 Number of elements/data mis-
match
The amount of data does not match the number
of elements.
7
110B Response too long The response length exceeds the communica-
tions buffer size (when the number of elements
is greater than the maximum number of ele-
ments for that service).
8
1100 Parameter error • Bit position is not “00.”
• The write data is out of the setting range.
• The command code or related information in
the operation command is wrong.
9
3003 Read-only error Variable type “C0” was written to. 10
2203 Operation error • The Communications Writing parameter is set
to “OFF” (disabled).
• Attempted to write to a parameter in setup
area 1 from setup area 0.
• Attempted to write to a protect parameter from
other than the protect level.
• Writing was carried out during AT execution.
• Processing is not possible by operation com-
mand.
• EEPROM error
11