96
Using the Key Protect Level Section 4-9
4-9 Using the Key Protect Level
4-9-1 Protection
• To move to the protect level, press the O and M Keys simultaneously for
at least three seconds in operation level or adjustment level. (See note.)
Note The key pressing time can be changed in the Move to Protect Level
Time parameter (advanced function setting level).
• The protect level protects parameters that are not changed during Con-
troller operation until operation is started to prevent them from being mod-
ified unintentionally.
There are four types of protection: operation/adjustment protect, initial
setting/communications protect, setting change protect, and PF Key pro-
tect.
• The protect level settings restrict the range of parameters that can be
used.
Operation/Adjustment
Protect
The following table shows the relationship between set values and the range
of protection.
• Parameters are not protected when the set value is set to 0.
• The default is 0.
Initial Setting/
Communications
Protect
This protect level restricts movement to the initial setting level, communica-
tions setting level, and advanced function setting level.
• The default is 1.
Setting Change
Protect
This protect level restricts key operations.
oapt
0
Level Set value
0123
Operation
level
PV Can be dis-
played
Can be dis-
played
Can be dis-
played
Can be dis-
played
PV/SP Can be dis-
played and
changed
Can be dis-
played and
changed
Can be dis-
played and
changed
Can be dis-
played
Others Can be dis-
played and
changed
Can be dis-
played and
changed
Cannot be
displayed and
moving to
other levels is
not possible
Cannot be
displayed and
moving to
other levels is
not possible
Adjustment level Can be dis-
played and
changed
Cannot be
displayed and
moving to
other levels is
not possible
Cannot be
displayed and
moving to
other levels is
not possible
Cannot be
displayed and
moving to
other levels is
not possible
icpt
1
Set
value
Initial setting level Communications
setting level
Advanced function
setting level
0 Possible to reach Possible to reach Possible to reach
1 Possible to reach Possible to reach Not possible to reach
2 Not possible to reach Not possible to reach Not possible to reach
wtpt
off
Set value Description
OFF Settings can be changed using key operations.
ON Settings cannot be changed using key operations. (The protect level
settings, however, can be changed.)

Table of Contents

Other manuals for Omron E5CN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5CN and is the answer not in the manual?

Omron E5CN Specifications

General IconGeneral
BrandOmron
ModelE5CN
CategoryTemperature Controller
LanguageEnglish

Related product manuals