Installation Environment (FHV series)
• Do not use the product in areas where flammable or explosive gases are present.
• Do not install the product close to high-voltage devices and power devices in order to secure the
safety of operation and maintenance.
• Do not install the product to a place where vibrations and/or impacts are expected.
• Do not install the product near to a device causing noises. if the product is installed in a noisy envi-
ronment and operational errors are caused, be sure to take shielding measures.
Power Supply and Wiring (FH series)
• Make sure to use the product with the power supply voltage specified by this manual or Instruction
sheet.
• Do not connect AC power source to Sensor Controller. If connects AC power source, it might be a
cause of the failure.
• Use the wire of a suitable size (AWG 16 to 12) according to the current consumption.
• Use a DC power supply with safety measures against high-voltage spikes (safety extra low-voltage
circuits on the secondary side).
• Keep the power supply wires as short as possible.
• Do the following confirmations again before turning on the power supply.
- Is the voltage and polarity of the power supply correct? (24 VDC)
- Is not the load of the output signal short-circuited?
- Is the load current of the output signal appropriate?
- Is not the mistake found in wiring?
- Is the voltage and polarity of the encoder power (ENC0_VDD/GND ENC1_VDD/GND) supply?
(5VDC)
• The recommended power supply for FH-L series is the S8VS- £££ 24 (manufactured by OMRON)
or S8VK-G- £££ 24 (manufactured by OMRON).
Power Supply and Wiring (FHV series)
• Make sure to use the product with the power supply voltage specified. If a DC voltage exceeding the
rating or an AC voltage is applied, the circuit parts may be burnt or exploded.
• Do not connect the power supply with polarity reversed.
• Use a DC power supply with safety measures against high-voltage spikes (safety extra low-voltage
circuits on the secondary side).
• Use an independent power source for this product. Do not use a shared power source.
• Never apply more than the rated voltage or AC power supply to this product. It may cause malfunc-
tion.
• The recommended power supplies are as follows:
- When attaching the lighting module, use S8VK-G06024 (OMRON) or S8VS-06024 (OMRON).
- When not attaching the lighting module, use S8VK-G06024 (OMRON) or S8VS-06024 (OMRON).
• Wire high-voltage cables or power cables separately from the cables of this product. If the same ca-
ble or duct is used, the product may receive induction and it may cause malfunctioning or breakage.
• Do not short-circuit load on the open collector output.
• Apply load not exceeding the rating.
• When wiring, put a crimp terminal of the specified size. Do not connect wires simply twisted together
to the power supply or terminal block directly.
Precautions for Safe Use
21