3-8
Updating Measurement Application
[Version-up]
The measurement application is possible to update.
Updating the measurement application allow you to utilize its new features in your Sensor Controller(s)
of the FH or FHV series.
Precautions for Correct Use
Older versions than Ver.6.30 do not allow the remote operation to update the measurement ap-
plication. Operate your Sensor Controller(s) to update it.
Additional Information
Remote Operation Tool, simulation software and software data of the version-up tool can be
downloaded for free if you register as a member. For details, please check the member registra-
tion sheet that is included in the sensor controller.
• By the Sensor Controller
• 3-8-1 By the Sensor Controller (FH Series) on page 3 - 38
• 3-8-2 By the Sensor Controller (FHV Series) on page 3 - 43
• By the Remote operation
• 3-8-3 By the Remote Operation on page 3 - 45
3-8-1
By the Sensor Controller (FH Series)
Items to Prepare
Precautions for Correct Use
• Set a USB memory stick or SD card to be used for the update to the read/write status. Other-
wise, the update will not be successfully completed.
• When you use a SD card, check the software version of the Sensor Controller. It should be
Ver. 5.20 or later.
• USB memory stick or SD card
Omron recommendation:
• USB memory stick - FZ-MEM2G or FZ-MEM8G
• SD card - HMC-SD291 or HMC-SD491
• PC
• Sensor Controller
• Accessories
• Power supply
• Mouse
• Monitor for connecting the Sensor Controller and the monitor cable.
• Software data of the version-up tool for the FH series
3 Basic Operations
3 - 38
FH/FHV Series Vision System User’s Manual (Z365-E1)