8-3-25
Troubleshooting
Symptom Setting Correction
The RUN signal is not out-
put.
Layout setup Select Layout setup from the Window menu and select
the RUN signal output check box for the layout to be used.
The layout of the Image con-
tainer window cannot be
changed.
-
Click the button in the upper right corner of the Image con-
tainer window when the Layout modification Pane is not dis-
played in the Main Window.
Cannot create a backup of
the layout settings.
-
The layout data is included in the system data and saved in
the Sensor Controller when you click Data save.
To save or load the settings to or from a file, click Save to
file or Load from file to save or load the system data and
scene group 0 data or the system settings data.
After loading the system settings, change to a layout num-
ber different from the one being edited, then switch back to
the layout number being edited. the updated contents will
be displayed.
An image of a window part
remains in the Main Window
when modifying the layout.
Layout modifica-
tion
When you finish modifying the layout, the display will be up-
dated and window parts will be displayed correctly.
Unable to output the meas-
urement result to an external
device after Switch layout is
executed.
Layout setup If Output is set to OFF in the Layout setup of the layout to
be used, the measurement result can not be externally out-
put immediately after launching the system, or after Switch
layout.
Even if you check Output in the measurement window of
the main screen, the setting selection for "Output" in the
Layout setup menu will be used when switching layouts.
Before executing measurement, set Output to ON in the
Layout setup menu of the layout to be used.
Editing contents are not re-
flected when you confirm the
Sensor Controller after edit a
layout by remote control.
Layout modifica-
tion
Change to a layout number different from the one was edit-
ed, then switch back to the edited layout number. The up-
dated contents will be displayed.
8 Setting Windows
8 - 63
FH/FHV Series Vision System User’s Manual (Z365-E1)
8-3 Arranging Windows [Layout Functions]
8
8-3-25 Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FHV7 series and is the answer not in the manual?

Omron FHV7 series Specifications

General IconGeneral
BrandOmron
ModelFHV7 series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals