6-6 Communications Settings
After setting, press the Write Button.
Communications Conditions for 1:N NT Links
Setting item Function Settings
Unit number Sets the unit number. 0 to 7
Communications Speed Sets the baud Communications speed. Standard, high-speed
Reference
The unit numbers that can be set depend on the type of host used, as follows:
C200HE(-Z):
Unit numbers 0 to 3 (up to four PTs for each port of the host)
C200HG(-Z), C200HX(-Z), CS1G/H, CS1G/H-H, CQM1H, CJ1G, and CJ1G/H-H:
Unit numbers 0 to 7 (up to eight PTs for each port of the host)
Refer to 4-2 1:N Host Connection for the host settings.
6-6-4 Setting Ethernet
To use Ethernet, select the Comm Tab from the System Menu and press the Enable Button.
The setting items for Ethernet will be displayed on the right side of the screen. Display and
set the network address, node address, IP address, subnet mask, and default gateway. Dis-
play the MAC address and IP address table display.
After setting, press the Write Button.
6-36

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NS5-SQ00 V2 Series and is the answer not in the manual?

Omron NS5-SQ00 V2 Series Specifications

General IconGeneral
BrandOmron
ModelNS5-SQ00 V2 Series
CategoryTouch terminals
LanguageEnglish

Related product manuals