3-8 Installing the Controller Link Interface Unit
2. At the end connected to the node, twist the mesh of the shield into a single wire. Leave
sufficient length at the tip of the twisted shield to be connected to a crimp terminal and
cover the remaining section with heat-shrink tubing. Cut all the shield mesh off at the end
not connected to the node.
Wire created by
twisting the shield
mesh.
Cover with heat-shrink tubing
Leave enough exposed wire to
attach to a crimp terminal.
3. Strip the ends of the signal wires far enough to attach to the crimp terminals. Twist the
wire strands together.
4. Cover the end of the cable at the point it was stripped to in step 1 with vinyl tape or heat-
shrink tubing.
Cover with vinyl tape or
heat- shrink tubing.
5. Attach crimp terminals to the shield wire and signal wires. Cover the connections with vi-
nyl tape or heat-shrink tubing.
Reference We recommend the Phoenix AI-series crimp terminals shown in the following diagram.
Phoenix’s ZA3 crimping tool can be used to attach these terminals.
Crimp terminal
Wire
Insert the wire and crimp the terminal to the wire.
3-52

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NS5-SQ00 V2 Series and is the answer not in the manual?

Omron NS5-SQ00 V2 Series Specifications

General IconGeneral
BrandOmron
ModelNS5-SQ00 V2 Series
CategoryTouch terminals
LanguageEnglish

Related product manuals