4-1
4-1 Installation Conditions
4
System Design
4System Design
4-1 Installation Conditions
Servo Drives
îš„ Space around Drives
 Install Servo Drives according to the dimensions shown in the following illustration to ensure
proper heat dispersion and convection inside the panel. Also if the Servo Drives are installed side
by side, install a fan for air circulation to prevent uneven temperatures from developing inside the
panel.
îš„ Mounting Direction
 Mount the Servo Drives in a direction (perpendicular) so that the model number can be seen
properly.
îš„ Operating Environment
 The environment in which Servo Drives are operated must meet the following conditions. Servo
Drives may malfunction if operated under any other conditions.
Ambient operating temperature: 0 to 55°C (Take into account temperature rises in the individual
Servo Drives themselves.)
Ambient operating humidity: 90% RH max. (with no condensation)
Atmosphere: No corrosive gases.
Servo
Drive
Servo
Drive
Servo
Drive
Side
panel
W
40 mm min.
W
100 mm min.
100 mm min.
Air
Air
Fan Fan
W = 10 mm min.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SMARTSTEP 2 SERIES and is the answer not in the manual?

Omron SMARTSTEP 2 SERIES Specifications

General IconGeneral
BrandOmron
ModelSMARTSTEP 2 SERIES
CategoryDC Drives
LanguageEnglish

Related product manuals