5-10
5-5 Electronic Gear
5
Operating Functions
Calculation Examples
 To operate with 2,000 pulses/rotation:
 To operate with 1,000 pulses/rotation:
 Conversely, to increase the resolution per rotation and operate with 40,000 pulses/rotation:
The setting ranges for Pn46, Pn47, and Pn4B, however, will be 1 to 10,000, so reduction to one
of the following is required.
Make reductions so that the values fit into the setting ranges, as shown above.
Related Parameter
The main function provided by the parameter related to electronic gears is given in the following
table.
10000 (Pn46) × 2
0 (Pn4A)
2000 (Pn4B)
10000 (Pn46) × 2
0 (Pn4A)
1000 (Pn4B)
10000 (Pn46) × 2
0 (Pn4A)
40000 (Pn4B)
2500 (Pn46) × 2
0 (Pn4A)
10000 (Pn4B)
1 (Pn46) × 2
0 (Pn4A)
4 (Pn4B)
or
Parameter
No.
Parameter name Explanation Reference
Pn40
Command Pulse
Multiplying Setting
The command pulses are multiplied by a factor of 2 or 4 when
using 90° phase difference signal inputs is selected as the in-
put format for the command pulses in the Command Pulse
Mode (Pn42).
Page 5-48

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SMARTSTEP 2 SERIES and is the answer not in the manual?

Omron SMARTSTEP 2 SERIES Specifications

General IconGeneral
BrandOmron
ModelSMARTSTEP 2 SERIES
CategoryDC Drives
LanguageEnglish

Related product manuals