EasyManuals Logo
Home>Omron>Controller>SYSMAC CS Series

Omron SYSMAC CS Series User Manual

Omron SYSMAC CS Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
110
Description of Operation Section 3-2
3-2-6 Simple Backup of Function Block Data to a Memory Card
(LCB01/03/05 Ver. 3.0 or Later)
Outline With LCB01/03/05 Ver. 3.0 or later, the following data (in addition to all data in
the CPU Unit) can be simultaneously and automatically backed up, restored,
or compared using the Memory Card for the Loop Controller RAM using the
simple backup operation.
• Function block data (See note 1.)
• Tag and comment data (block diagram information, tags, comments, and
annotations)
Operation
commands
Cold start Possible, but
backup may
not be normal
--- Possible The data backed up in the Mem-
ory Card may not be correct. If
the data is not correct, a function
block database error (RAM) will
occur and A42410 will turn ON
when recovery is attempted.
Hot start Possible --- Simple backup operation ends
normally.
Stop Possible --- Simple backup operation ends
normally.
System operation validation Possible --- Possible Simple backup operation ends
normally.
Action validation Possible --- Possible Simple backup operation ends
normally.
All clear Possible, but
backup may
not be normal
--- Possible The data backed up in the Mem-
ory Card may not be correct. If
the data is not correct, a function
block database error (RAM) will
occur and A42410 will turn ON
when recovery is attempted.
Tuning Possible --- Possible Simple backup operation ends
normally.
Password protection Possible ---
Possible
The simple backup operation will
be cancelled if password protec-
tion is set.
Version check Possible ---
Possible
Simple backup operation ends
normally.
Backup/
recovery
Backup
(transfer to
flash mem-
ory in Loop
Controller)
While
transfer-
ring
Possible --- Possible Simple backup operation ends
normally.
While
stopped
Not possible MCPWR indica-
tor flashes on
CPU Unit and
simple backup
operation ends in
an error.
Not possi-
ble
Simple backup operation will not
be possible.
Recovery (transfer from
flash memory to RAM in
Loop Controller)
Possible, but
backup may
not be normal
--- Possible The data backed up in the Mem-
ory Card may not be correct. If
the data is not correct, a function
block database error (RAM) will
occur and A42410 will turn ON
when recovery is attempted.
Online operation from CX-Process
Tool
During
simple
backup
operation
Results on CX-
Process Tool
when operation
is not possible
Backup
continued/
interrupted
Data in Memory Card resulting
from simple backup operation

Table of Contents

Other manuals for Omron SYSMAC CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CS Series and is the answer not in the manual?

Omron SYSMAC CS Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CS Series
CategoryController
LanguageEnglish

Related product manuals