Key [10]
Telephone line monitor
Telephone line cannot be found for 30 seconds. "Telephone line monitor" is enabled at address 206. This
trouble condition can also trigger an alarm when the system is armed, if activated at address 206. It will
also be stored in "event list". Restoration of telephone line can be reported by programming address 183.
Key [11]
Fire trouble
The zone wire has been cut on *zone 3 (when its zone definition is "24 hour fire"). Fire zone *key [3] also
flashes. If programmed at address 174, it will be reported to the central.
*Zone 12 and key [12] for software prior to 0.98.
END-USER PROGRAMMING
MASTER AND USER CODES
(default master 474747)
[ENTER] + master code + code number (2 digits)+ new code (4 or 6 digits, 0 to 9) + [ENTER].
Use [2ND] to erase a code.
Master code = 00 ([10][10]) Full access to all system functions.
User codes = 01-16 (728, 738, 748, 748ES) and 01-08 (718, 728L)
(01 - can modify access codes. All user code priorities can be programmed
at addresses 200, 202, 204, using the installer code.)
Note: [2ND] key flashes if location is empty (no code programmed).
"ONE-KEY" USER PROGRAMMING COMMANDS
Several panel features can be programmed quickly, without entering addresses or section numbers. Select
"one-key access" programming mode by pressing [ENTER], followed by INSTALLER, MASTER OR USER
CODE (depending on feature you wish to activate, only certain codes will be functional). Then press the sin-
gle key (listed below) corresponding to the feature you wish to enable.
KEY
[9] Program "auto arming" time:
(accessible to Master and User 1 only)
Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes + [ENTER].
To disable program, [2ND], [2ND].
[MEM] Program "panel time"
(all 3 codes)
Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes + [ENTER]
[BYP] Test report
(all 3 codes)
Reporting is enabled at address 206, key [11], [12]. A value must be entered at address 175,
and both telephone and account numbers should be programmed.
[TRBL] Call Espload via telephone
(all 3 codes)
Panel and PC ID numbers (addresses 001-004) and PC download phone number
(addresses 060-067) must be programmed.
[AWAY] Answer Espload
(all 3 codes)
This feature is available when using the ADP-1 adapter. In
Espload
, "blind dial" must
be activated in "modem setup" section and panel phone number programmed
.
[STAY] Cancel communication attempts
(master code and user 1 can only stop calls from/to Espload.)
Until next reportable event.
(installer code - all communication)
[STAY] Reset to default panel settings
(installer code only)
Connect reset jumper on circuit board (see wiring diagram).
Press [ENTER] + installer code + [STAY], remove reset jumper.
[2],[6] Installer test mode
(installer code only)
In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep
(long) indicates test is "off". The bell will squawk during walk testing to indicate open zones.
[2],[7] Streamlined value entry
(installer code only)
(see Installer programming page 21.)
Note: When communicating with Espload, programming mode cannot be accessed.
19