Time for "no movement" report (Address 253)
Range 001 to 255 X 15 minutes, (
default 8 hours, 032)
. System will automatically arm after programmed
number of minutes of inactivity if enabled at address 206, key [6], or will transmit code programmed at
address 190.(Maximum time 63.75 hours) Also see "Special timing functions" page 20.
Timed programmable output (PGM) (Address 254)
Range 001 to 127 seconds or 128 (1 minute) to 255 (127 minutes) (add number of minutes to 128;
i.e. For 5 minutes = 128 + 5 = 133
For 127 minutes = 128 + 127 = 255
Applied to PGM 1 and 2 if selected at address 195.(Maximum time, 127 minutes)
INSTALLER LOCK (Address 255)
If 147 is programmed at address 255, all installer programming will be locked and will not return to
default values when the system is reset.
PANEL RESET TO FACTORY PROGRAMMING DEFAULTS
(Note: Panel will not revert to default settings following reset when installer lock (address 255) is enabled.)
Power down reset
(1) Remove AC and battery to power down the unit.
(2) Connect a jumper between "reset jumper" pins.
(3 Connect AC or battery.
(4) Wait 3 seconds.
(5) Remove jumper.
To conduct a panel reset without powering down, the installer code is required.
Panel reset without power down
(1) Connect a jumper between "reset jumper" pins.
(2) Press [ENTER] + installer code + [STAY].
(3) Remove jumper.
The factory default installer code will be reinstated and all panel programming for addresses 005 - 243
reverts to factory defaults.
33
WARRANTY
Warranty conditions for the
ESPRIT
may vary from country to country. Please consult your local
dealer for complete warranty information. In all cases, the warranty does not cover malfunctions
arising from installer error or failure to follow installation/operation instructions, nor does it apply to
damages due to causes beyond the control of Paradox Security Systems, such as lightning, exces-
sive voltage, mechanical shock or water damage.
LIABILITY
Under no circumstances shall Paradox Security Systems be held liable for any direct or indirect
damages, loss of anticipated profits, loss of time, or any other losses incurred by the buyer in con-
nection with the purchase, installation, operation or failure of this product.
WARNING
This security system should undergo frequent testing. However, despite regular testing, and due
to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to
fail to perform as expected.
IM8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit 738 and is the answer not in the manual?

Paradox Esprit 738 Specifications

General IconGeneral
BrandParadox
ModelEsprit 738
CategoryControl Panel
LanguageEnglish

Related product manuals