Enable keypad Panic signals (Address 208)
Key [1] "on" = Panic 1 (keys [1] and [3]) enabled
Key [2] "on" = Panic 2 (keys [4] and [6]) enabled
Key [3] "on" = Panic 3 (keys [7] and [9]) enabled
Keypad Panic options (Address 208)
Key [4] "off" = Panic 1 silent Key [5] "off" = Panic 2 silent Key [6] "off" = Panic 3 silent
Key [4] "on" = Panic 1 audible Key [5] "on" = Panic 2 audible Key [6] "on" = Panic 3 fire
Silent operation
(Address 206, key [9])
When panic keys ([1] and [3], [4] and [6], [7] and [9]) are pushed simultaneously for 2 seconds, a single
confirmation beep is sounded, codes programmed at addresses 184, 185, and 186 are transmitted and
the alarm latches, flashing the keypad "armed" light until reset by a user code.
Audible operation
When panic keys are pushed in addition to alarm codes being transmitted, the alarm output (bell, siren)
will activate until reset by a user code or until the bell cut-off time (address 250) expires.
Fire operation
Same as audible operation except that bell/siren output will be pulsed (intermittent "on"/"off")
"One key" arming enable (Address 208)
Key [7] "on" = Pushing key [10] will "full" arm system for 2 seconds.
Key [8] "on" = Pushing key [11] will "stay" arm system for 2 seconds.
User/access code length (Address 208)
Key [9] "off" = 6 digit user/access codes and installer code.
Key [9] "on" = 4 digit user/access codes and installer code.
Tamper/wire Fault Definitions (Address 208)
Note: If key [10] and key [11] are both "off", this means that tamper and wire faults will not be
recognized. "See Loop configuration" pages 9, "Tamper/wire Fault Definition and Options",
page 12, and "Tamper/wire Fault Definition table" in the "Programming Guide".
Beep on exit delay (Address 208)
Key [12] "on" = the keypad will sound on exit delay. (Frequency of intermittent beeps increases during
the last 10 seconds of the exit delay period.)
Zone restore transmission (Address 208)
Key [
BYP
] "off" = If zone is closed, restoration will be transmitted after "bell time out" period (address 250).
Key [BYP] "on" = Restoration code transmitted as soon as zone is closed.
Zones with EOL resistors (Address 208, key [MEM])
See "Loop configuration and Options" pages 9.
Always report disarm (Address 208)
Key [TRBL] "off" = always report disarm codes (regular "opening" and "closing" reports)
Key [TRBL] "on" = report disarm code only after alarm.
Exclude AC from Trouble Display (Address 210, key [2ND])
Key ="on": AC failure will not light the [TRBL] key when [TRBL] key is pressed.
May still be viewed as trouble condition by pressing
29