Zone disabled (Address 210, key [1])
Used in conjunction with zone 3 (zone 12 for software versions prior to 0.98) when programmed as a fire zone.
Key ="on": burglar alarm zone associated with fire zone is disabled so that a wire fault on the fire zone
(fire trouble) will not cause an alarm on the associated burglar zone.
Panel Fire Zone Associated Zone
728, 728L 3 6 (ATZ)
738 12 (ATZ) 9
748 12 24 (ATZ)
ARMING OPTIONS
Auto arm (Address 210, Key [2])
Key ="off":when system auto arms (on time or "no movement"), "regular" arming will take place.
(if all zones are closed).
Key ="on": when system auto arms (on time or “no movement”), "STAY" arming will take place.
(if all zones are closed). If zone PARTITIONING is programmed (address 206, key [8]),
System “A” will arm. See also "Special timing functions" page 20.
Regular arming (Address 210, key [3])
Key ="off": system will not arm with a zone in alarm condition unless "auto bypass (away)"arming is
used.
Key ="on": system will automatically "auto bypass (away)" arm when regular arming code is entered.
Zones will be bypassed if so enabled at addresses 236 and 238 and "partial arm" code
will be sent (if programmed at address 187.)
Arming inhibit on battery failure/low voltage (Address 210, key [4])
Key ="on": system will not arm if Battery Failure /Low Voltage is present.
Arm inhibit on "Tamper/wire Fault" (Address 210, key [5])
Key ="on": system will not arm if Tamper fault is present. MUST BE RESET BY INSTALLER
BEFORE SYSTEM CAN BE ARMED AGAIN.
No tamper bypass (Address 210, key [6])
Key ="off":Device tamper will not follow zone bypass.
Key ="on": Device tamper will follow zone bypass.
Only bypass code reported on bypass arming (Address 210, key [7])
Key ="off":when system is armed with zones bypassed, partial arming code (address 187) will be
transmitted, followed by the arming code (addresses 88-103).
Key ="on": when system is armed with zones bypassed, only partial arming code (address 187) will
be transmitted.
Advanced Technology Zoning (ATZ) (Address 210, key [8])
Key ="on":Enabled (When enabled permits two zones per circuit. See zone configurations,
page 9a, 10-12.) (Not available on 718 and 748ES Panels)
Key ="off":Single zone per loop.
Note: This function is enabled at address 208 for software versions prior to 0.98.
Audible Trouble Warning (Address 210, Key [9])
Key ="off":Trouble conditions cause intermittent audible trouble warning on keypad. To silence,
push [TRBL] + [CLEAR]. (software versions 0.98 and beyond)
Keypad zone supervision
(Applies only to software versions 1.4 and beyond)***
Keypad zone supervision permits the system to verify the presence of a keypad. When a keypad is not
detected, the keypad zone is regarded as “open”. A maximum of two keypad zones can be supervised
using this feature.
30