Continuous measurement
During the continuous measurement, a measurement series is
continuously sampled, and the max./min. values m of the series are
displayed. To do this, move the device along a base surface or an
edge from which you want to the measure lengths. For example, you
can measure how parallel two opposite walls are or measure the
extreme (max./min.) values while using a function.
Press the continuous measurement button
w to start the
continuous measurement. After a short time, the measured value
appears on the display 1.
Press the continuous measurement button w again to end the
continuous measurement. Pressing the MEAS button r or the
Back/Clear button 6 will also end the continuous measurement.
The max./min. values m are now shown on the display 1 along
with the most recently measured value.
Note: (1) Repeat the described steps to take another measurement,
if necessary. (2) The length measurement mode symbol l flashes
during the measurement in continuous measurement mode.
(3) Addition, subtraction, area and volume measurements cannot
be performed in this mode. (4) If no button is pressed for 30 seconds,
the laser beam and the backlighting of the display 1 automatically
switch off. (5) If no button is pressed for 3 minutes, the device au-
tomatically switches off. (6) Successful measurements are retained
after the automatic shut-off.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parkside PLEM 50 C4 and is the answer not in the manual?

Parkside PLEM 50 C4 Specifications

General IconGeneral
BrandParkside
ModelPLEM 50 C4
CategoryAnalytical Instruments
LanguageEnglish

Related product manuals