RADWIN2000UserManual Release2.8.30 10‐3
LinkCompatibility
ThefileissavedinthespecifiedfolderasDiagnosticsInformation.txt
LinkCompatibility
LinkCompatibilityindicatestheversioncompatibilityusingsoftwaretraps.Asnewhardware
orsoftwareisaddedtoexistingnetworkscompatibilityissuesmayarise.Anincompatibility
issueisindicatedtotheuserbyachangeofcoloroftheLinkStatusboxontheMainMenu
window.Trapmessages(canbeviewedintheEventsLog)indicatetheproblemsorlimitations
andsuggestupgradeswhenappropriate.
ThefollowingLinkStatusmessagesaregiven:
fullCompatibility‐differentsoftwareversionsweredetectedthatarefullycompatible.The
messageindicatesthatanupgradeisavailable.
restrictedCompatibility‐differentsoftwa reversionsweredetectedthatoperatecorrectly.
However,newfeaturesarenotsupported.
softwareUpgradeRequired‐differentsoftwareversionsweredetectedallowinglimited
operation.Themessageis,thatasoftwareupgradeisrequired.
versionsIncompatibility‐differentsoftwareversionsweredetectedthatareincompatible.
Youneedtoperformlocalupgrades.
Table10‐2:LinkCompatibilityTrapMessages
LinkState
LinkState
text
Link
Status
Color
Site
Description
fullCompatibility Active Green
Software
Upgrade
Available
restrictedCompatibility
Active‐
Software
Version
mismatch
Magenta
(Sameas
authentic
ation
error)
Software
Upgrade
Recommende
d
softwareUpgradeRequir
ed
Active–
Software
Upgrade
Required
Brown
(Major)
Software
Upgrade
Required
versionsIncompatibility
NotActive
‐Software
Upgrade
Required
Red
Local
Software
Upgrade