CHAPTER 10
68 Raven RS1™ and RS Lite™ Calibration and Operation Manual
523874 .13
Memory communication
error.
Power cycle the RS1. If the issue persists, contact Raven
technical service.
523875 .13 SCU software out of date. Update the RS1 software.
523875 .7
MCM software
compatibility.
Update Machine Control Module (MCM) software
version.
523898 .31 OEM engage error.
Field computer on-screen engage switch not supported.
Use the machine engage switch to initiate autosteer.
523913 .31 GPS invalid authorization.
Some correction types require an unlock code. Either
the code was not entered correctly or an existing code
has expired.
Review Chapter 8, Feature Unlock Codes for additional
information on entering unlock codes. Contact a local
Raven dealer or Raven technical service for additional
support.
523916
.13 SC1 software out of date. Update the SC1 ECU software version.
.14
RS Lite software out of
date.
Update the RS Lite software version.
523918 .2
GPS receiver error: input
overrun.
Power cycle the RS1.
523919 .31
GPS receiver error:
jammer detected.
523920 .2
GPS receiver error: IMU
communication failure.
523921 .31
GPS receiver error:
tracking mode.
523922 .31
GPS receiver error: digital
filter enabled.
523923 .0 VSN data invalid warning.
VSN is unable to provide valid row guidance. Check the
camera feed and solution quality from the VSN object
pool Home page.
523924 .0 VSN data invalid error. VSN guidance vectors not valid. Restart the VSN.
523925 .2
No row camera
communication.
VSN times out after 10 seconds. Check cabling and
connections.
523926 .31 No user activity.
Check operator switch settings and operator switch
cabling and connections if present.
523927 .31 VSN only needs TC.
VSN requires a task controller. Open a job on a field
computer to use VSN guidance.
523928 .13 Invalid factory calibration
1. Restart the RS1.
2. Contact your local Raven dealer.
573927 .31 VSN only job required. Start a job on the field computer or UT to function.
Code ID Description Recommended Actions

Table of Contents

Other manuals for Raven RS1/HDU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven RS1/HDU and is the answer not in the manual?

Raven RS1/HDU Specifications

General IconGeneral
BrandRaven
ModelRS1/HDU
CategoryControl Systems
LanguageEnglish

Related product manuals