Technical Bulletin PAGE: 1/1
Reissued: 22-Dec-15
RTB Reissue
The areas outlined in red in the photos were corrected.
Please add the following caution in the field service manual in this section:
Replacement and Adjustment > Electrical Components > PSU
POWER SUPPLY UNIT:100V:280W
POWER SUPPLY UNIT:200V:280W
NEVER touch the areas outlined in red in the photos below to prevent electric shock
caused by residual charge.
Residual charge of about 100V-400V remains on the PSU board for several months
even when the board has been removed from the machine after turning off the
machine power and unplugging the power cord.