RIGOL Chapter 2 Command System
2-98 MSO1000Z/DS1000Z Programming Guide
:MATH:FFT:HCENter
:MATH:FFT:HCENter <cent>
:MATH:FFT:HCENter?
Set or query the center frequency of the FFT operation result, namely the frequency
relative to the horizontal center of the screen. The default unit is Hz.
 When the FFT mode is set to TRACe, the range of <cent> is from 0 to (0.4 x FFT
sample rate). Wherein, FFT sample rate equals to screen sample rate, that is,
100/horizontal timebase.
When the FFT mode is set to MEMory, the range of <cent> is from 0 to (0.5 x FFT
sample rate). Wherein, FFT sample rate equals to memory sample rate
(:ACQuire:SRATe?).
 Step = Horizontal Scale of the FFT operation result/50.
The query returns the current center frequency in scientific notation.
:MATH:FFT:HCENter 10000000 /*Set the center frequency of the FFT operation result
to 10MHz*/
:MATH:FFT:HCENter? /*The query returns 1.000000e+07*/
:MATH:OPERator
:MATH:FFT:MODE
:TIMebase[:MAIN]:SCALe
:MATH:FFT:HSCale
:MATH:FFT:MODE
:MATH:FFT:MODE <mode>
:MATH:FFT:MODE?
Set or query the FFT mode.
 TRACe: denotes that the data source of the FFT operation is the data of the
waveform displayed on the screen.
 MEMory: denotes that the data source of the FFT operation is the data of the
waveform in the memory.
The query returns TRAC or MEM.
:MATH:FFT:MODE TRACe /*Set the FFT mode to TRACe*/
:MATH:FFT:MODE? /* The query returns TRAC*/