RIGOL Chapter 2 Command System
2-154 MSO1000Z/DS1000Z Programming Guide
:TIMebase:DELay:OFFSet
Syntax
:TIMebase:DELay:OFFSet <offset>
:TIMebase:DELay:OFFSet?
Description
Set or query the delayed timebase offset. The default unit is s.
Parameter
Name
Type
Range
Default
<offset>
Real
-(LeftTime - DelayRange/2) to
(RightTime - DelayRange/2)
0
Explanation
LeftTime = 6 x MainScale - MainOffset
RightTime = 6 x MainScale + MainOffset
DelayRange = 12 x DelayScale
Wherein, MainScale is the current main timebase scale of the oscilloscope,
MainOffset is the current main timebase offset of the oscilloscope, and DelayScale is
the current delayed timebase scale of the oscilloscope.
Return Format
The query returns the delayed timebase offset in scientific notation.
Example
:TIMebase:DELay:OFFSet 0.000002 /*Set the delayed timebase offset to 2μs*/
:TIMebase:DELay:OFFSet? /*The query returns 2.0000000e-06*/
Related
Commands
:TIMebase[:MAIN]:SCALe
:TIMebase[:MAIN]:OFFSet
:TIMebase:DELay:SCALe

Table of Contents

Other manuals for Rigol DS1104Z Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1104Z Plus and is the answer not in the manual?

Rigol DS1104Z Plus Specifications

General IconGeneral
BrandRigol
ModelDS1104Z Plus
CategoryTest Equipment
LanguageEnglish

Related product manuals