RIGOL Chapter 2 Command System
2-134 MSO1000Z/DS1000Z Programming Guide
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry <val>
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry?
Set or query the ramp symmetry (the percentage that the rising period takes up in the
whole period) of the specified source channel.
If omitted, the operation is
performed on source 1 by
default
The query returns the symmetry in scientific notation, such as 5.000000e+01.
:FUNCtion:RAMP:SYMMetry 50 /*Set the ramp symmetry of source 1 to 50%*/
:FUNCtion:RAMP:SYMMetry? /*The query returns 5.000000e+01*/
[:SOURce[<n>]]:FUNCtion[:SHAPe]
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <Amplitude>
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]?
Set or query the output amplitude of the specified source channel. The default unit is Vpp.
If omitted, the operation is
performed on source 1 by
default
Related to the output
impedance
HighZ: 20mVpp to 5Vpp
50Ω: 10mVpp to 2.5Vpp
You can use the [:SOURce[<n>]]:OUTPut[<n>]:IMPedance command to set the output
impedance.
The query returns the amplitude in scientific notation, such as 1.0000000e+00.
:VOLTage 2 /*Set the output amplitude of source 1 to 2V*/
:VOLTage? /*The query returns 2.0000000e+00*/