Chapter 2 Command System RIGOL
MSO1000Z/DS1000Z Programming Guide 2-189
:TRIGger:WINDows
Command List:
:TRIGger:WINDows:SOURce
:TRIGger:WINDows:SLOPe
:TRIGger:WINDows:POSition
:TRIGger:WINDows:TIMe
:TRIGger:WINDows:ALEVel
:TRIGger:WINDows:BLEVel
:TRIGger:WINDows:SOURce
Syntax
:TRIGger:WINDows:SOURce <source>
:TRIGger:WINDows:SOURce?
Description
Set or query the trigger source in windows trigger.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
CHANnel1
Return
Format
The query returns CHAN1, CHAN2, CHAN3, or CHAN4.
Example
:TRIGger:WINDows:SOURce CHANnel2 /*Set the trigger source to CH2*/
:TRIGger:WINDows:SOURce? /*The query returns CHAN2*/
:TRIGger:WINDows:SLOPe
Syntax
:TRIGger:WINDows:SLOPe <type>
:TRIGger:WINDows:SLOPe?
Description
Set or query the windows type in windows trigger.
Parameter
Name
Type
Range
Default
<type>
Discrete
{POSitive|NEGative|RFALl}
POSitive
Explanation
POSitive: trigger on the rising edge of the input signal when the voltage level is
greater than the preset high trigger level.
NEGative: trigger on the falling edge of the input signal when the voltage level is
lower than the preset low trigger level.
RFALl: trigger on any edge of the input signal when the voltage level meets the
preset trigger level.
Return
Format
The query returns POS, NEG, or RFAL.
Example
:TRIGger:WINDows:SLOPe NEGative /*Set the windows type to NEGative*/
:TRIGger:WINDows:SLOPe? /*The query returns NEG*/

Table of Contents

Other manuals for Rigol DS1104Z Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1104Z Plus and is the answer not in the manual?

Rigol DS1104Z Plus Specifications

General IconGeneral
BrandRigol
ModelDS1104Z Plus
CategoryTest Equipment
LanguageEnglish

Related product manuals