Chapter 2 Command System RIGOL
MSO1000Z/DS1000Z Programming Guide 2-113
The number of negative pulses that fall from above the threshold upper limit to
below the threshold lower limit.
The number of rising edges that rise from below the threshold lower limit to above
the threshold upper limit.
The number of falling edges that fall from above the threshold upper limit to below
the threshold lower limit.
3. Delay and Phase
The time difference between the rising edges of source 1 and source 2. Negative
delay indicates that the selected rising edge of source 1 occurred after the selected
rising edge of source 2.
The time difference between the falling edges of source 1 and source 2. Negative
delay indicates that the selected falling edge of source 1 occurred after the selected
falling edge of source 2.
Phase difference calculated according to "Delay 1→2" and the period of source
1, expressed in degree. The calculation formula is as shown below.
Phase difference calculated according to "Delay 1→2" and the period of source
1, expressed in degree.The calculation formula is as shown below.
360
1
Delay
Phase
Period
  
Wherein,
denotes "Phase 1→2" or "Phase 1→2",
denotes "Delay 1→2"
or "Delay 1→2" and
denotes the period of source 1.