Chapter 2 Command System RIGOL
MSO7000/DS7000 Programming Guide 2-137
[:SOURce[<n>]] Commands
The [:SOURce[<n>]] commands are used to set the relevant parameters of the built-in function/arbitrary
waveform generator. <n> can set to 1 or 2, which indicates the corresponding built-in function/arbitrary
waveform generator channel. When <n> or :SOURce[<n>] is omitted, by default, the operations are
carried out on AWG GI. The commands are only available for the MSO7000 model installed with the
function/arbitrary waveform generator option.
Command List:
[:SOURce[<n>]]:FREQuency[:FIXed]
[:SOURce[<n>]]:PHASe[:ADJust]
[:SOURce[<n>]]:PHASe:INITiate
[:SOURce[<n>]]:FUNCtion[:SHAPe]
[:SOURce[<n>]]:FUNCtion:RAMP:SYMMetry
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate]:OFFSet
[:SOURce[<n>]]:PULSe:DCYCle
[:SOURce[<n>]]:MOD:TYPE
[:SOURce[<n>]]:MOD:AM[:DEPTh]
[:SOURce[<n>]]:MOD:AM:INTernal:FREQuency
[:SOURce[<n>]]:MOD:FM:INTernal:FREQuency
[:SOURce[<n>]]:MOD:AM:INTernal:FUNCtion
[:SOURce[<n>]]:MOD:FM:INTernal:FUNCtion
[:SOURce[<n>]]:MOD:FM[:DEVIation]
[:SOURce[<n>]]:APPLy?
[:SOURce[<n>]]:APPLy:NOISe
[:SOURce[<n>]]:APPLy:PULSe
[:SOURce[<n>]]:APPLy:RAMP
[:SOURce[<n>]]:APPLy:SINusoid
[:SOURce[<n>]]:APPLy:SQUare
[:SOURce[<n>]]:APPLy:USER
[:SOURce[<n>]]:OUTPut[<n>][:STATe]
[:SOURce[<n>]]:OUTPut[<n>]:IMPedance

Table of Contents

Other manuals for Rigol DS7024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS7024 and is the answer not in the manual?

Rigol DS7024 Specifications

General IconGeneral
BrandRigol
ModelDS7024
CategoryTest Equipment
LanguageEnglish

Related product manuals