Chapter 2 Command System RIGOL
MSO7000/DS7000 Programming Guide 2-31
:BUS<n>:FLEXray (Option)
The :BUS<n>:FLEXray commands are used to set the relevant parameters for FLEXray decoding.
Command List:
:BUS<n>:FLEXray:BAUD
:BUS<n>:FLEXray:SOURce
:BUS<n>:FLEXray:SPOint
:BUS<n>:FLEXray:STYPe
:BUS<n>:FLEXray:BAUD
Syntax
:BUS<n>:FLEXray:BAUD <baud>
:BUS<n>:FLEXray:BAUD?
Description
Sets or queries the signal rate of FlexRay decoding. The default unit is bps.
Parameter
Name
Type
Range
Default
<n>
Discrete
{1|2|3|4}
——
<baud>
Discrete
{2500000|5000000|10000000}
10000000
Return
Format
The query returns 2500000, 5000000, or 10000000.
Example
:BUS1:FLEXray:BAUD 2500000 /*Sets the signal rate of FlexRay decoding to
2500000 bps.*/
:BUS1:FLEXray:BAUD? /*The query returns 2500000.*/
:BUS<n>:FLEXray:SOURce
Syntax
:BUS<n>:FLEXray:SOURce <source>
:BUS<n>:FLEXray:SOURce?
Description
Sets or queries the source channel of FlexRay decoding.
Parameter
Name
Type
Range
Default
<n>
Discrete
{1|2|3|4}
——
<source>
Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
D12|D13|D14|D15|CHANnel1|CHANnel2|CHAN
nel3|CHANnel4}
CHANnel1
Return
Format
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14,
D15, CHAN1, CHAN2, CHAN3, or CHAN4.
Example
:BUS1:FlexRay:SOURce D0 /*Sets the source channel of FlexRay decoding to D0.*/
:BUS1:FlexRay:SOURce? /*The query returns D0.*/

Table of Contents

Other manuals for Rigol DS7024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS7024 and is the answer not in the manual?

Rigol DS7024 Specifications

General IconGeneral
BrandRigol
ModelDS7024
CategoryTest Equipment
LanguageEnglish

Related product manuals