PowerFlex Digital DC Drive User Manual - Publication 20P-UM001C-EN-P - July 2008
Programming and Parameters 3-33
DYNAMIC CONTROL
Adaptv Regulator
186 [Adaptive Joint 1]
Defines a range above and below the value set in Par 184 [Adaptive
Spd 1] within which there is a linear change in gain from parameter
set 1 to parameter set 2 in order to prevent jumps in the adaptive
speed regulator. The value in this parameter is defined as percentage
of the value defined Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
6.11
0.00 / 200.00
%
184
187 [Adaptive Joint 2]
Defines a range above and below the value set in Par 185 [Adaptive
Spd 2] with in which there is a linear change in gain from parameter
set 2 to parameter set 3 in order to prevent jumps in the adaptive
speed regulator. The value in this parameter is defined as percentage
of the value defined Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
6.11
0.00 / 200.00
%
185
188 [Adaptive P Gain1]
Proportional gain for the range from zero to the value set in Par 184
[Adaptive Spd 1]. The value in this parameter is defined as
percentage of the value defined in Par 93 [Spd Reg Kp Base].
Default:
Min/Max:
Units:
10.00
0.00 / 100.00
%
93,
184
189 [Adaptive I Gain1]
Integral gain for the range from zero to Par 184 [Adaptive Spd 1]. The
value in this parameter is defined as percentage of the value defined
Par 94 [Spd Reg Ki Base].
Default:
Min/Max:
Units:
1.00
0.00 / 100.00
%
94,
184
190 [Adaptive P Gain2]
Proportional gain for the range of values defined beginning with the
value of Par 184 [Adaptive Spd 1] to the value defined in Par 185
[Adaptive Spd 2]. The value in this parameter is defined as
percentage of the value defined Par 93 [Spd Reg Kp Base].
Default:
Min/Max:
Units:
10.00
0.00 / 100.00
%
93,
184,
185
191 [Adaptive I Gain2]
Integral gain for the range of values defined beginning with the value
of Par 184 [Adaptive Spd 1] to the value defined in Par 185 [Adaptive
Spd 2]. The value in this parameter is defined as percentage of the
value defined Par 94 [Spd Reg Ki Base].
Default:
Min/Max:
Units:
1.00
0.00 / 100.00
%
94,
184,
185
192 [Adaptive P Gain3]
Proportional gain for the range of values beginning above the value
defined in Par 185 [Adaptive Spd 2]. The value in this parameter is
defined as percentage of the value defined Par 93 [Spd Reg Kp
Base].
Default:
Min/Max:
Units:
10.00
0.00 / 100.00
%
93,
185
193 [Adaptive I Gain3]
Integral gain for the range of values beginning above the value
defined in Par 185 [Adaptive Spd 2]. The value in this parameter is
defined as percentage of the value defined Par 94 [Spd Reg Ki Base].
Default:
Min/Max:
Units:
1.00
0.00 / 100.00
%
94,
185
File
Group
No.
Parameter Name & Description
See page 3-2 for symbol descriptions
Values
Related
A
A
A
A
A
A
A
A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation PowerFlex series and is the answer not in the manual?

Rockwell Automation PowerFlex series Specifications

General IconGeneral
BrandRockwell Automation
ModelPowerFlex series
CategoryDC Drives
LanguageEnglish

Related product manuals