PowerFlex Digital DC Drive User Manual - Publication 20P-UM001C-EN-P - July 2008
A-4 Supplemental Drive Information
IP20 (NEMA UL/Type Open)
Watts Loss
Watts loss data shown below is based on the rated current of the drive.
Important:For drives with 230V input, rated 150 HP / 521 A, the cooling
fans must be powered by an external 230V 50/60 Hz power
supply at terminals U3 & V3.
Frame
Drive Current Rating
Code
(1)
(1)
Refer to Catalog Number Explanation on page Preface-4, positions 8-10 for corresponding drive HP rating,
armature amp rating and field amp rating.
Total Watts
Loss (W)
Fans
@ 230V @ 460V Voltage (V) Rated Current (A) Air Capacity (m
3
/h)
A7P0 4P1
131 – – –
9P0 6P0
012 010
020 014
–019
029 027 186 – – –
038 035
254
Internal power supply
80055 045
–052
073 073 408 160
093 086
476 160
110 –
– 100
553 160
– 129
B 146 167
781 320
180 –
218 207 939 320
265 250 1038 320
– 330 1248 320
360 412
1693 680
434 –
C 521 495 2143 230 0.75 1050
– 667 2590 230 0.75 1050