PowerFlex Digital DC Drive User Manual - Publication 20P-UM001C-EN-P - July 2008
Application Notes C-15
Auto/Manual Notes
1. Manual control is exclusive. If a HIM or Terminal Block takes manual
control, no other device can take manual control until the controlling
device releases control.
2. If a HIM has manual control and power is removed from the drive, the
drive will return to Auto mode when power is reapplied.
Speed Feedback
The value of parameters 169 [Encoder PPR] and 162 [Max Feedback Spd]
must be inside the allowed area shown in the figure below regardless of the
value selected in Par 414 [Fdbk Device Type].
100
100
200 300 400 500 600 700 800
900
1000 2000 3000 4000
200
300
400
500
600
700
800
900
1000
2000
3000
4000
5000
6000
10000
Par 162 [Max Feedback Spd]
Par 169 [Encoder PPR]
Allowed Area