PowerFlex Digital DC Drive User Manual - Publication 20P-UM001C-EN-P - July 2008
Programming and Parameters 3-11
Monitor File
File
Group
No.
Parameter Name & Description
See page 3-2 for symbol descriptions
Values
Related
MONITOR
Speed Meters
44 [Speed Ref A]
First speed reference for the drive. Negative values apply to four
quadrant drives only.
Note: This parameter is assigned to analog input 1 (terminals 1
& 2, Par 70 [Anlg In1 Sel]) by default, but can be assigned to any
analog input.
Default:
Min/Max:
Units:
Read Only
–/+ Par 45 [Max Ref Speed]
(1)
RPM
45
(1)
The value of [Max Ref Speed] cannot exceed 8192 RPM.
47 [Speed Ref A Pct]
First speed reference for the drive as a percentage of the value
defined in Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
48 [Speed Ref B]
Second speed reference for the drive. Negative values apply to
four quadrant drives only.
Note: This parameter can be assigned to an analog input.
Default:
Min/Max:
Units:
Read Only
–/+ Par 45 [Max Ref Speed]
(1)
RPM
45
(1)
The value of [Max Ref Speed] cannot exceed 8192 RPM.
49 [Speed Ref B Pct]
The second speed reference for the drive as a percentage of the
value defined in Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
110 [Ramp In]
Total reference value input to the ramp in RPM.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
111 [Ramp In Pct]
Total reference value input to the ramp as a percentage of Par
45 [Max Ref Speed].
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
113 [Ramp Out]
Output of the ramp in RPM.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
114 [Ramp Out Pct]
Output of the ramp as a percentage of Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
117 [Speed Reg In Pct]
Total reference value input to the Speed Regulator as a
percentage of Par 45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
118 [Speed Reg In]
Total reference value input to the Speed Regulator in RPM.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
121 [Spd Feedback Pct]
Actual speed as a percentage of the Par 45 [Max Ref Speed].
Note: This parameter is assigned to analog output 1 (terminals
21 and 22, Par 66 [Anlg Out1 Sel]) by default, but can be
assigned to any analog output.
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45,
923
122 [Spd Feedback]
Actual speed in RPM.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
384 [Spd Ref Out Pct]
Output of the Speed Reference selection as a percentage of Par
45 [Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+100.00
%
45
385 [Speed Ref Out]
Output of the Speed Reference selection.
Default:
Min/Max:
Units:
Read Only
–/+32766
RPM
420 [Encoder Speed]
Actual speed measured by the digital encoder.
Default:
Min/Max:
Units:
Read Only
–/+8192
RPM
414

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation PowerFlex series and is the answer not in the manual?

Rockwell Automation PowerFlex series Specifications

General IconGeneral
BrandRockwell Automation
ModelPowerFlex series
CategoryDC Drives
LanguageEnglish

Related product manuals