3-70 Programming and Parameters
PowerFlex Digital DC Drive User Manual - Publication 20P-UM001C-EN-P - July 2008
INPUT / OUTPUT
Digital Outputs
581 [Dig Out Status]
Status of the standard digital outputs and relay outputs on the drive and on the
optional I/O Expansion circuit board (if present).
Read Only
629 [Relay Out 2 Sel]
Selects the source of the value that drives the N.O. relay
between the terminals 75 and 76.
Refer to “Option Definitions” on page 3-69
.
Options:
Default: 5 = “Ready”
1267
1268
1269
1270
1271
1272
1273
1274
[Inversion Out 1]
[Inversion Out 2]
[Inversion Out 3]
[Inversion Out 4]
[Inversion Out 5]
[Inversion Out 6]
[Inversion Out 7]
[Inversion Out 8]
Reverses the digital output signal.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
1275 [Inversion Relay2]
Inverts the signal for Relay Output 2.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
1392 [Relay Out 1 Sel]
Selects the source of the value that drives the N.O. relay
between the terminals 35 and 36.
Refer to “Option Definitions” on page 3-69
.
Options:
Default: 25 = “Contactor”
File
Group
No.
Parameter Name & Description
See page 3-2 for symbol descriptions
Values
Related
Relay Out2
Relay Out1
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Digital Out8
Digital Out7
Digital Out6
Digital Out5
Digital Out4
Digital Out3
Digital Out2
Digital Out1
Default
00xxxxxx00000000
Bit
1514131211109876543210
0 = “Not Used” 8 = “Spd Limited” 16 = “Encoder Err” 24 = “ContactDB”
1 = “Spd Zero Thr” 9 = “Fault” 17 = “Diam Calc” 25 = “Contactor”
2 = “Spd Thresh” 10 = “Power Loss” 18 = “Input1 Cmp” 26 = “Alarm”
3 = “At Speed” 11 = “UserDefinedA” 19 = “Diam Reached” 27 = “Running”
4 = “CurrentLimit” 12 = “UserDefinedB” 20 = “Speed Match” 28 = “Jogging”
5 = “Ready” 13 = “Stop Control” 21 = “Accelerating” 29 = “Active”
6 = “Ramp Pos” 14 = “Field Loss” 22 = “Decelerating”
7 = “Ramp Neg” 15 = “Spd Fbk Loss” 23 = “Brake Cmd”
A
A
0 = “Not Used” 8 = “Spd Limited” 16 = “Encoder Err” 24 = “ContactDB”
1 = “Spd Zero Thr” 9 = “Fault” 17 = “Diam Calc” 25 = “Contactor”
2 = “Spd Thresh” 10 = “Power Loss” 18 = “Input1 Cmp” 26 = “Alarm”
3 = “At Speed” 11 = “UserDefinedA” 19 = “Diam Reached” 27 = “Running”
4 = “CurrentLimit” 12 = “UserDefinedB” 20 = “Speed Match” 28 = “Jogging”
5 = “Ready” 13 = “Stop Control” 21 = “Accelerating” 29 = “Active”
6 = “Ramp Pos” 14 = “Field Loss” 22 = “Decelerating”
7 = “Ramp Neg” 15 = “Spd Fbk Loss” 23 = “Brake Cmd”