BRP-Rotax
MAINTENANCE MANUAL LINE
EXCEEDING THE MAX. PERMISSIBLE OIL TEMPERATURE
General note
ATTENTION
If the max. permissible oil temperature is exceeded, other limits are often ex-
ceeded, too, e.g. the cylinder head temperature. Please observe the relevant
instructions.
NOTE
Any exceeding of the max. admissible oil temperature must be entered by the pilot
into the engine log book, stating duration extant of excessive temperature and
pertinent detail.
Read out the ECU data memory and check the data for details of increased oil tempera-
ture. Perform the corresponding inspections/repairs depending on the functional defects
found.
Proceed as instructed
in table 4
Proceed as instructed
in table 3
Operating limit
(See Operators Manual 912 i Series)
160 °C
(320 °F)
0
15 min. Time
Figure 5.13: Overview and proceed
Effectivity: 912 i Series
Edition 2/Rev. 0
05–50–00
Page 23