8-14. Miscellaneous Settings
A variety of changes can be made to settings, depending on the indoor unit being used.
Wind direction ( ap) indicator, operation mode indicator, time display (24 hour, AM/PM), heat max temp
For information about the  ap function, refer to the users’ manual of the unit being used.
(These settings are saved in nonvolatile memory in the remote control, so even when its batteries are changed,
the settings do not have to be made again.)
First check the display of the remote control when the unit is stopped and then make any desired settings.
How to Operate
While holding down the buttons below, every time
is pressed the remote control’s display changes.
Whatever is being displayed when you release is set.
Setting Item Operation Button Setting Content Remote Control Display
Remote control  ap display
setting for when
is pressed
Press
while pressing
Models with movable  aps
Swing only models
Models w/o lamps None
Remote control operation
mode display setting when
is pressed
Press
while pressing
Heat Pump (with Auto)
Heat Pump (without Auto)
Dedicated air conditioner
Clock display setting
Press
while pressing
24 Hour
AM/PM
Max possible temperature
setting in the Heat mode
Press
while pressing
Maximum heating
temperature
range is 26°C – 30°C
8-15. Before Requesting Service
Before requesting service, please check the followings.
Problem Cause Solution
The unit doesn’t work
even when is pressed
on the remote control.
The power to the indoor unit is not ON. Make sure the power to the indoor unit is ON.
Is the Normal/Stop All switch in the Stop All position?
(See Page 8-4)
Switch it to the Normal position and cancel
operation.
Are the remote control’s batteries dead? Change the batteries.
Is there a mismatch between the display lamp and
cooling/heating or is it set to something other than
Auto? (The operating lamp stays lit, while the timer
lamp and the standby lamp blink alternately.)
Change the operating mode.
Do the addresses match one another? Check the addresses of the receiver
*1
and the
remote control. (See Page 8-7)
The air conditioner
starts and stops on its
own.
Has the timer been set to repeat? Check the timer settings.(See Page 8-6)
” is displayed on the
remote control when the
unit is stopped.
An error has occurred in the non-volatile memory. Please contact your sales outlet.
Although the unit is for air conditioning only, either Auto or Heat is indicated
in the display.
Make settings to the remote control’s operation
mode display. (See the above table.)
After putting the batteries in the remote control, even when it is operated,
the display does not change.
Press the Reset button on the remote control.
(See Page 8-5)
The timer cannot be set. Make the settings when the remote control is
in Operation Display. (See Page 8-6)
If the problem persists even after you check the foregoing items, stop the unit, disconnect the power to the indoor
unit and contact the dealer where the product was purchased with the model number and problem you are having.
As it is dangerous, under no circumstances should you undertake repairs yourself.
Further, when the receiver’s
*2
lamps are blinking; please contact your retailer with that information.
*1 RCS-SS80BG.WL is an operation panel
*2 RCS-SS80BG.WL is a display
8-10
SM830160-03ClassicPAC-iA4.ind1010SM830160-03ClassicPAC-iA4.ind1010 2010/02/1610:31:182010/02/1610:31:18

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo SPW-C366VH8 and is the answer not in the manual?

Sanyo SPW-C366VH8 Specifications

General IconGeneral
BrandSanyo
ModelSPW-C366VH8
CategoryAir Conditioner
LanguageEnglish

Related product manuals