6 Technical data
-Bxx3x -Bxx4x -Bxx6x -Bxx1x -Bxx2x -Bxx5x
Laser class 1 1 1 1 1 1
Sensing range 100 ... 2500
mm
1
100 ... 1800
mm
1
100 ... 3800
mm
1
100 ... 1600
mm
1
100 ... 1400
mm
1
100 ... 1800
mm
1
Sensing range max. 50 ... 2500
mm
1
50 ... 1800
mm
1
50 ... 3800
mm
1
50 ... 1600
mm
1
50 ... 1400
mm
1
50 ... 1800
mm
1
Light spot diameter/distance < 14.0 mm /
2500 mm
< 12.0 mm /
1800 mm
< 18.0 mm /
3800 mm
< 11.0 mm /
1600 mm
<10.0 mm /
1400 mm
< 12.0 mm /
1800 mm
Supply voltage V
S
DC 10 ... 30
V
2
DC 10 ... 30
V
2
DC 10 ... 30
V
2
DC 10 ... 30
V
2
DC 10 ... 30
V
2
DC 10 ... 30
V
2
Output current I
max.
≤ 100 mA ≤ 100 mA ≤ 100 mA ≤ 100 mA ≤ 100 mA ≤ 100 mA
Max. switching frequency 1,000 Hz
3
30 Hz
3
100 Hz
3
1000 Hz
3
30 Hz
3
100 Hz
3
Max. response time 0.5 ms
4
16.7 ms
4
5 ms
4
0.5 ms
4
16.7 ms
4
5 ms
4
Enclosure rating IP67 IP67 IP67 IP67 IP67 IP67
Protection class III III III III III III
Circuit protection A, B, C
5
A, B, C
5
A, B, C
5
A, B, C
5
A, B, C
5
A, B, C
5
Ambient operating temperature -35 ... +50
°C
6
-35 ... +50
°C
6
-35 ... +50
°C
6
-35 ... +50
°C
6
-35 ... +50
°C
6
-35 ... +50
°C
6
Warm-up time <15 min <15 min <15 min <15 min <15 min <15 min
IO-Link 1.1 1.1 1.1 1.1 1.1 1.1
Communication mode COM2 COM2 COM2 COM2 COM2 COM2
Distance value measuring range 50 ... 2500
mm
50 ... 1800
mm
50 ... 3800
mm
50 ... 1600
mm
50 ... 1400
mm
50 ... 1800
mm
Distance value-resolution 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm
Distance value reproducibility 2.3 ... 6.1
mm
78
0.9 ... 1.3
mm
78
1.1 ... 3.0
mm
78
2.7 ... 8.0
mm
78
1.1 ... 1.5
mm
78
1.2 ... 3.0
mm
78
Distance value-accuracy typ. ±15 mm typ. ±15 mm typ. ±15 mm typ. ±20 mm
(50 ... 1000
mm)
±15 mm
(1000 ...
1600 mm)
typ. ±20 mm
(50 ... 1000
mm)
±15 mm
(1000 ...
1400 mm)
typ. ±20 mm
(50 ... 1000
mm)
±15 mm
(1000 ...
1800 mm))
1
Object with 6 % ... 90 % remission (based on standard white DIN 5033)
2
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
ss
3
With light / dark ratio 1:1
4
Signal transit time with resistive load
5
A = U
V
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
C = Interference suppression
6
As of T
U
= 45°C a supply voltage of V
max
= 24 V is permissible.
7
Equivalent to 1 σ.
8
6% ... 90% remission (based on standard white DIN 5033)
7 Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
TECHNICAL DATA 6
8018110.1BVZ / 2021-05-18 | SICK
Subject to change without notice
11