VPN tunnel between SCALANCE M-800 and security CPs
4.2 Secure VPN tunnel with PSK
SCALANCE M-800 Getting Started
156 Getting Started, 06/2015, C79000-G8976-C337-04
4.2.2.3
Downloading the configuration to the CP and saving the M-800 configuration
Downloading the configuration to the CP
1. Close the Security Configuration Tool.
2. In HW Config, select the "Station" > "Save and Compile" menu.
3. Download the new configuration to the security module using the "PLC" > "Download to
Module …" menu.
For CP 1628: If the download was completed free of errors, the security module
restarts automatically and the new configuration is activated.
For CP 343-1 Advanced or CP 434-1 Advanced: Restart the S7 CPU following the
download, to activate the new configuration
Saving the SCALANCE M-800 configuration
1. In STEP 7, open the Security Configuration Tool with the "Edit" > "Security Configuration
Tool" menu command.
2. In the content area, select the "M-800" and select the menu command "Transfer" > "To
module(s) …".
3. Save the configuration file "Projectname.M-800.txt" in your project directory.
Result
The following file will be saved in the project directory:
Configuration file: projectname.M-800.txt
The configuration file contains the exported configuration information for the SCALANCE M-
800. Follow the instructions in the configuration file.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE M826-2 and is the answer not in the manual?

Siemens SCALANCE M826-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE M826-2
CategoryNetwork Router
LanguageEnglish

Related product manuals