Connecting SCALANCE M-800 to WAN
1.2 Connecting M81x to ADSL
SCALANCE M-800 Getting Started
34 Getting Started, 06/2015, C79000-G8976-C337-04
6. Repeat the password in "Password Confirmation" to confirm it. The entries must match.
7. Click the "Set Values" button.
The password for the "admin" user is changed. The changes take immediate effect.
Changing the IP settings of the M81x
The following IP address settings are made for the devices in this configuration example:
Admin PC 192.168.100.20 255.255.255.0
1. Click "System" > "Agent IP" in the navigation area.
2. Enter 192.168.100.1 in "IP Address" and 255.255.255.0 in "Subnet Mask".
3. Click "Set Values".
The IP address is adjusted automatically in the address bar of the Web browser. The
Web browser on the Admin PC can no longer access Web Based Management because
its IP settings no longer match.
4. On the Admin PC, open the Control Panel with the menu command "Start" > "Control
Panel".