Programming Example for Standard Function Blocks
9.2 Settings
PtP coupling and configuration of CP 340
Manual, 04/2011, A5E00369892-03
149
9.2 Settings
Settings in the CPU via STEP 7
You must configure your controller setup with STEP 7:
Slot 1: Power supply
Slot 2: CPU
Slot 4: Digital input, IB0 and IB1
Slot 5: Digital output, QB4 and QB5
Slot 6: CP 340, start address P288
Settings on the CP 340
You cannot make any hardware settings on the CP 340.
All relevant data are configured via STEP 7, including the parameters for the CP 340, using
the CP 340: Point–to–Point Communication, Assigning Parameters, and then download
those data to the CPU.
You can run the program example for the computer link without making changes in the
application program with:
3964(R) procedure
ASCII driver with "on expiry of character delay time" end criterion
ASCII driver with "on receipt of fixed telegram length" end criterion.
For the ASCII driver with the "on receipt of the end character(s)" end criterion, you must also
program the end codes.
The program example for the printer can be run with the printer driver only.
The "read and control RS 232C accompanying signals" functions can only be carried out
with the ASCII driver. A prerequisite is that you have not set the “Automat. control of V24
signals" parameter on the "Transfer" tab.

Table of Contents

Other manuals for Siemens SIMATIC CP 340

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC CP 340 and is the answer not in the manual?

Siemens SIMATIC CP 340 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC CP 340
CategoryComputer Hardware
LanguageEnglish

Related product manuals