Installing and connecting the device
3.3 Connecting the device
SIMATIC IPC547G
46 Operating Instructions, 04/2020, A5E49948632-AA
WARNING
Operation only in TN networks
The device is designed exclusively for operation on grounded power supply systems (TN
networks per VDE 0100 Part 100 or IEC 60364-1). Operation with non-grounded or
impedance-grounded systems is not permitted.
Rated voltage
The permitted nominal voltage of the device must conform with local mains voltage.
I/O devices
NOTICE
Fault caused by I/O devices
The connection of I/O devices can cause faults in the device. The result may be personal
injury and damage to the machine or plant. Note the following:
Connect only I/O devices which are approved for industrial applications in accordance
with EN 61000-6-2/IEC 61000-6-2.
Non-hot-plug capable I/O devices may only be connected when the power supply to the
device is switched off.
Damage through regenerative feedback
Regenerative feedback of voltage to ground by a connected or installed component can
damage the device.
Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any
voltage to the device. Regenerative feedback is generally not permitted.
See also
Switching off the device (Page 63)

Table of Contents

Other manuals for Siemens Simatic series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic series and is the answer not in the manual?

Siemens Simatic series Specifications

General IconGeneral
BrandSiemens
ModelSimatic series
CategoryIndustrial PC
LanguageEnglish

Related product manuals