Expanding and assigning parameters to the device
6.4 Memory expansion
SIMATIC IPC547G
Operating Instructions, 04/2020, A5E49948632-AA
77
Requirement
The front door is open; see "Opening the front door (Page 76)".
The device is fully disconnected from the mains voltage; see section "Switching off the
device (Page 63)".
All connection cables are unplugged.
T10 screwdriver
Procedure
1.
Remove the captive screw.
2.
Push the enclosure cover back.
3.
Lift up and remove the enclosure cover.
6.4 Memory expansion
Depending on the device version there are two or four slots for memory modules on the
motherboard. You can expand the memory up to 64 GB, for devices with motherboard
D3445-S up to 32 GB. Of which 3.2 GB can be used in a 32-bit operating system.
The following memory modules can be installed:
Motherboard
Number of slots
2 GB *
4 GB
8 GB *
16 GB *
Max. possible
D3445 2 - X X X 32 GB
D3446
4
-
X
X
X
64 GB
* The following memory module types are approved: DDR4 SDRAM PC4-2400T/s
A detailed description of possible memory expansion options is available in the manual of
the motherboard on the supplied "Documentation and Drivers" DVD.

Table of Contents

Other manuals for Siemens Simatic series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic series and is the answer not in the manual?

Siemens Simatic series Specifications

General IconGeneral
BrandSiemens
ModelSimatic series
CategoryIndustrial PC
LanguageEnglish

Related product manuals