EasyManuals Logo
Home>Siemens>Engine>SIMOTICS XP

Siemens SIMOTICS XP User Manual

Siemens SIMOTICS XP
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Operation
8.2 Switching on the machine
1MB..1/2/3/4 - shaft heights 63 ... 355
Operating Instructions, 06/2020, A5E44455710A
103
WARNING
Explosion hazard
If the anti-condensation heating is switched on during operation, the temperature class or
the maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
Only switch on the anti-condensation heating after the motor has been switched-off.
Comply with the data stamped on the plate of the anti-condensation heating, if available.
8.2 Switching on the machine
1. If at all possible, run the machine without load and check that it is running smoothly.
2. If it runs perfectly, connect a load.
NOTICE
Thermal overload of motors connected directly to the line supply
In addition to the load torque, the ramp-up (accelerating) time is essentially influenced
by the moment of inertia to be accelerated. While ramping up when connected to the
line supply, the inrush (starting) current is a multiple of the rated current. This can result
in thermal overload. This can damage the motor.
As a consequence, when ramping up, observe the following:
Monitor the ramp-up time and number of consecutive starts.
Comply with the limit values and/or ramp-up conditions specified in the catalog or the
order documentation.
3. If this is possible using the available measuring equipment, check the bearing and stator
winding temperatures.
8.3 Switching off the external fan
Do not immediately switch off the separately-driven (external) fan after switching off the
machine. First wait for the machine to cool down. This will prevent the accumulation of
residual heat.
8.4 Switching on again after an emergency switching-off
Check the machine before recommissioning the driven machine after an Emergency Off.
Eliminate all the causes that have led to the emergency off

Table of Contents

Other manuals for Siemens SIMOTICS XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP and is the answer not in the manual?

Siemens SIMOTICS XP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP
CategoryEngine
LanguageEnglish

Related product manuals