8.5 Stoppages
1MB..1/2/3/4 - shaft heights 63 ... 355
104 Operating Instructions, 06/2020, A5E44455710A
8.5 Stoppages
The stoppage is a shutdown for a period of time, during which the machine is stopped but
remains at the location of use.
Under normal ambient conditions, e.g. the stationary machine is not exposed to any
vibration, no increased level of corrosion, ... then the following measures are required.
Longer non-operational periods
For longer non-operational periods (> 1 month), either operate the machine or at least
turn the rotor regularly, approximately once per month.
If attached, remove the rotor shipping brace before you turn the rotor.
Carefully comply with the information in Section "Switching on" before switching on to
recommission the motor.
NOTICE
Restricted motor function
If not used for longer periods of time, material damage or complete motor failure can occur.
If the motor is out of service for a period of more than 12 months, then environmental
effects can damage the motor.
Apply suitable corrosion protection, preservation, packaging and drying measures.
Switching on the anti-condensation heating, if available
Only switch on the anti-condensation heating after the motor has been switched off. Comply
with the data stamped on the plate of the anti-condensation heating, if available.
Taking the machine out of service
Detailed information on how to take the machine out of service is provided in Chapter
Preparing for use (Page 33).
Lubricating before recommissioning
NOTICE
Dry running bearings
Bearings can be damaged if they do not have sufficient grease.
Re-grease the bearings if they have been out of service for more than one year. The
shaft must rotate so that the grease can be distributed in the bearings. Follow the
instructions on the lubricant plate.
More information can be found in Chapter Installing rolling bearings (Page 125).

Table of Contents

Other manuals for Siemens SIMOTICS XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP and is the answer not in the manual?

Siemens SIMOTICS XP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP
CategoryEngine
LanguageEnglish

Related product manuals