Safety information
2.13 Special conditions for use
1MB..1/2/3/4 - shaft heights 63 ... 355
18 Operating Instructions, 06/2020, A5E44455710A
EPS 18 ATEX 1 202 X, EPS 18 ATEX: 1 202 X
It is not permissible to operate groups of motors connected to the converter. The rated
converter current may correspond as a maximum to twice the rated motor current. It is only
permissible to operate the motor with a SINAMICS converter or a converter that is
comparable. When commissioning the system, with reference to the rated voltage (UN) of
the winding insulation, carefully ensure that no converter-related overvoltages with a peak
value exceeding (1.1 * 2 * UN) occur at the terminals of the electric motor. If anti-
condensation heating is used, then an interlock circuit must ensure that the anti-
condensation heating can only be operated when the motor is shut down. If the three-phase
motor is cooled using an external fan, then it must be carefully ensured that the motor can
only be operated when the external fan is switched on.

Table of Contents

Other manuals for Siemens SIMOTICS XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP and is the answer not in the manual?

Siemens SIMOTICS XP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP
CategoryEngine
LanguageEnglish

Related product manuals